Skip to content
inside your peptides.
Search
Testing & COAs

Read the report.
Not the badge.

“Third-party tested” is a starting point, not an answer. A certificate of analysis shows what was measured, on which sample, using which method.

The number is not the whole story

99% pure is not
99% of the vial.

HPLC peak-area purity is a ratio of detected chromatographic signals under the reported method. It is not automatically a mass percentage of the full vial contents.

Water, salts, response differences, co-eluting material, and substances the detector does not see can affect interpretation. Identity and measured content require their own evidence.

A reading checklist, not sample data

Three different questions.

  • Identity
    Does the analytical evidence support the stated material?
  • Purity
    What share of the method's detected signal belongs to the reported main peak?
  • Content
    How much of the stated analyte was measured?
Peptide-purity measurement research · NIST
Five measures · five different questions

Read every result in context.

No single line answers all five.

01 · Identity

Is the material consistent with the label?

Look for the method, expected identity, and observed result. Mass-spectrometry evidence can support identity, but expected mass alone does not uniquely establish every sequence or structure.

Check: the reported material and method, not just a purity peak.

02 · Purity

What did this method detect?

Read the reported HPLC peak-area percentage with the detector and separation method. It is not a direct measurement of all vial contents, and different substances can produce different detector responses.

Check: the chromatogram, method, and stated reporting basis.

03 · Measured content

How many milligrams were measured?

Compare the label claim with the measured analyte content, units, and method. Total powder mass is not necessarily peptide content. Read measurement uncertainty where the report provides it.

Check: measured mg and their analytical basis, not the label repeated as a result.

04 · Endotoxin

What endotoxin signal was found?

Read the assay, result, units, reporting limit, and stated criterion. Endotoxin testing is separate from a test for living organisms. Method suitability matters, including when recombinant reagents are used.

Check: a result with units and method, rather than an unexplained “pass.”

05 · Microbial screen

Which organisms or signals were screened?

A culture-based screen and a DNA-based screen answer different questions. Read the target organisms, method, sample quantity, and detection limit. A negative result is limited to that screen's scope.

Check: the exact screen. Do not relabel it as sterility testing.

The certificate matches. Does the lot?

Connect the document
to the material.

A lab's name on a PDF is not enough. Verify the issuing source and identify precisely what was submitted for analysis.

Even a matching report describes tested samples. It does not demonstrate that each vial was tested or that all products from a supplier have the same coverage.

  1. Issuing lab & source
    Find the laboratory independently. Use its own lookup or contact route where available, rather than relying only on a seller-hosted copy.
  2. Accession or report number
    Use the lab's identifier to check the report, reported results, and any revision.
  3. Exact material & lot
    Match the named material and lot number to the research material in question. A different lot is not the same evidence.
  4. Client & sample description
    Check who submitted it and what was tested: bulk material, a finished vial, or another sample. A client field alone does not establish chain of custody.
  5. Dates & sample scope
    Read the receipt, test, and issue dates where reported. Check sample quantity, methods, detection limits, and the number of units tested.
Keep learning

Read the methods behind the words.

Primary-source foundations · checked 17 September 2026

Measurement research

Peptide purity is a measurement problem.

NIST's peptide-purity research describes characterization and value assignment, rather than treating one chromatographic percentage as a complete answer.

Read the NIST publication
Measurement literacy

A reported number has uncertainty.

Read NIST's explanation of measurement uncertainty as a foundation for interpreting laboratory results.

Read the NIST explainer
FDA guidance · March 2026

Endotoxin methods need suitability checks.

FDA's revised guidance and accompanying explanation include recombinant reagents. A method still needs to be suitable for its intended material and purpose.

Read the FDA explanation
Disclosed supplier connection

Two separate
research resources.

Published analytical documents and access to research supply are different things. Choose the resource you need.

Published lab reports

Open the documentation hub, then check the exact lot, accession, source, and test coverage.

View published lab reports

Qualified research supply

The next lab's research-account route is for qualified laboratory research, not personal treatment or patient testing.

Research supply at the next lab